Determining a building's construction type is dependent on quite a number of different factors and requires a keen eye for detail. If you would like to be able to identify a building's construction type, start with Step 1 below for an overview of how it's done. You will also find specific information on all six building types.
 
Determining a building's construction type is dependent on quite a number of different factors and requires a keen eye for detail. If you would like to be able to identify a building's construction type, start with Step 1 below for an overview of how it's done. You will also find specific information on all six building types.
[[Category:Woodworking]]
+
[[Category: Woodworking]]
  
 
== Steps ==
 
== Steps ==
 
=== Overview for Assessing Construction Type===
 
=== Overview for Assessing Construction Type===
# How building class is determined: <br><br> All buildings must be classified into one of six construction classes (see number 3). Classification of a building class is based on two factors: building elements and fire-resistance rating.  These factors may not be included in the submission/documentation, in which case additional information will need to be requested.  
+
# How building class is determined: All buildings must be classified into one of six construction classes (see number 3). Classification of a building class is based on two factors: building elements and fire-resistance rating.  These factors may not be included in the submission/documentation, in which case additional information will need to be requested.  
 
#* '''Building elements''': The building materials used in the construction of the following elements are the foundation for classification, be they wood, steel, or masonry.
 
#* '''Building elements''': The building materials used in the construction of the following elements are the foundation for classification, be they wood, steel, or masonry.
 
#** Structural frame
 
#** Structural frame
Line 15: Line 15:
 
#* '''Fire-resistance rating''': This is the other factor in determining construction class.  The building materials used in the construction of the building elements above will have a fire-resistance rating.  Fire-resistance rating typically means the duration for which a passive fire protection system can withstand a standard fire resistance test. This can be quantified simply as a measure of time (ex. 0 hours, 1 hour, or 2 hours), or it may entail a host of other criteria involving other evidence of functionality or fitness for purpose.
 
#* '''Fire-resistance rating''': This is the other factor in determining construction class.  The building materials used in the construction of the building elements above will have a fire-resistance rating.  Fire-resistance rating typically means the duration for which a passive fire protection system can withstand a standard fire resistance test. This can be quantified simply as a measure of time (ex. 0 hours, 1 hour, or 2 hours), or it may entail a host of other criteria involving other evidence of functionality or fitness for purpose.
 
#** '''“Minimum” rule''': It is important to remember when selecting the construction class that the building is only as strong as its weakest element.  For example, a masonry building may have an unprotected wood roof.  The wood roof is the weakest member such that it has '''no''' fire-resistance.  Thus, the construction class would be Joisted Masonry (see below).  Now imagine this same building with a metal deck roof.  So long as the supporting members of the building do not contain wood then this building would be Masonry Noncombustible (see below).
 
#** '''“Minimum” rule''': It is important to remember when selecting the construction class that the building is only as strong as its weakest element.  For example, a masonry building may have an unprotected wood roof.  The wood roof is the weakest member such that it has '''no''' fire-resistance.  Thus, the construction class would be Joisted Masonry (see below).  Now imagine this same building with a metal deck roof.  So long as the supporting members of the building do not contain wood then this building would be Masonry Noncombustible (see below).
# What to ask: <br><br> To determine the ISO class of the building, we must therefore know the following composition of the building elements:
+
# What to ask: To determine the ISO class of the building, we must therefore know the following composition of the building elements:
 
#* Structural frame
 
#* Structural frame
 
#* Bearing walls (interior and exterior)
 
#* Bearing walls (interior and exterior)
Line 21: Line 21:
 
#* Roof construction
 
#* Roof construction
 
#* What the fire rating of the materials
 
#* What the fire rating of the materials
# Building classes:<br><br> All construction types must be classified into the following (all of which are explained extensively below):
+
# Building classes: All construction types must be classified into the following (all of which are explained extensively below):
 
#* '''Frame Construction''' (ISO Class I, IBC Type V)
 
#* '''Frame Construction''' (ISO Class I, IBC Type V)
 
#* '''Joisted Masonry''' (ISO Class 2, IBC Type III, IBC Type IV)
 
#* '''Joisted Masonry''' (ISO Class 2, IBC Type III, IBC Type IV)
Line 28: Line 28:
 
#* '''Modified Fire Resistive''' (ISO Class 5, IBC Type IB)
 
#* '''Modified Fire Resistive''' (ISO Class 5, IBC Type IB)
 
#* '''Fire Resistive''' (ISO Class 6, IBC Type IA)
 
#* '''Fire Resistive''' (ISO Class 6, IBC Type IA)
# International Building Code (IBC) versus Insurance Services Office (ISO):<br><br> These are two major sources identifying construction types, both of which will be addressed in the construction types outlined below. ISO is traditionally what insurance companies use to denote type, whereas IBC is what architects and builders use. While one company may use ISO classifications, many submission documents may reference IBC classifications and it is important to be able to convert this to an ISO classification. (There have been situations where a frame building has been incorrectly classified as fire resistive because the submittal was read incorrectly!) The following explains what is expected under both:  
+
# International Building Code (IBC) versus Insurance Services Office (ISO): These are two major sources identifying construction types, both of which will be addressed in the construction types outlined below. ISO is traditionally what insurance companies use to denote type, whereas IBC is what architects and builders use. While one company may use ISO classifications, many submission documents may reference IBC classifications and it is important to be able to convert this to an ISO classification. (There have been situations where a frame building has been incorrectly classified as fire resistive because the submittal was read incorrectly!) The following explains what is expected under both:  
 
#* '''International Building Code (IBC)''': This is a model building code developed by the International Code Council (ICC). It has been adopted throughout most of the United States.  A large portion of the International Building Code deals with fire prevention. It differs from the related International Fire Code in that the IBC handles fire prevention in regards to construction and design and the fire code handles fire prevention in an ongoing basis.  Parts of the code reference other codes including the International Plumbing Code, the International Mechanical Code, the National Electric Code, and various National Fire Protection Association Standards. IBC is more descriptive and also includes A or B types of construction for each class.
 
#* '''International Building Code (IBC)''': This is a model building code developed by the International Code Council (ICC). It has been adopted throughout most of the United States.  A large portion of the International Building Code deals with fire prevention. It differs from the related International Fire Code in that the IBC handles fire prevention in regards to construction and design and the fire code handles fire prevention in an ongoing basis.  Parts of the code reference other codes including the International Plumbing Code, the International Mechanical Code, the National Electric Code, and various National Fire Protection Association Standards. IBC is more descriptive and also includes A or B types of construction for each class.
 
#** '''A is protected''', meaning that all structural members of a building or structure have an additional fire rated coating or cover by means of sheetrock, spray on, or other approved method.  The additional fire rated coating or cover extends the fire resistance of the structural members by at least 1 hour.
 
#** '''A is protected''', meaning that all structural members of a building or structure have an additional fire rated coating or cover by means of sheetrock, spray on, or other approved method.  The additional fire rated coating or cover extends the fire resistance of the structural members by at least 1 hour.
Line 35: Line 35:
  
 
=== Frame Construction (ISO Class I, IBC Type V) ===
 
=== Frame Construction (ISO Class I, IBC Type V) ===
# Classification: <br><br>Frame construction is ISO Class 1.  ISO Class 1 encompasses IBC Type VA and IBC Type VB.  Regardless of whether the IBC classification is A (protected) or B (unprotected) the ISO Class is 1.
+
# Classification: Frame construction is ISO Class 1.  ISO Class 1 encompasses IBC Type VA and IBC Type VB.  Regardless of whether the IBC classification is A (protected) or B (unprotected) the ISO Class is 1.
 
# Building elements:
 
# Building elements:
 
#* Frame buildings are buildings with exterior walls, floors, and roofs with combustible construction — or buildings with exterior walls of noncombustible or slow-burning construction with combustible floors and roofs.
 
#* Frame buildings are buildings with exterior walls, floors, and roofs with combustible construction — or buildings with exterior walls of noncombustible or slow-burning construction with combustible floors and roofs.
Line 58: Line 58:
  
 
=== Joisted Masonry (ISO Class 2, IBC Type III, IBC Type IV) ===
 
=== Joisted Masonry (ISO Class 2, IBC Type III, IBC Type IV) ===
# Classification: <br><br>Joisted Masonry construction is ISO Class 2.  ISO Class 2 encompasses IBC Type IIIA and IBC Type IIIB.  Regardless of whether the IBC classification is A (protected) or B (unprotected) the ISO Class is 2. IBC Type IV is Heavy Timber construction and is considered ISO Class 2. The reason is that the heavy timbers perform well and do not fail early in a fire.
+
# Classification: Joisted Masonry construction is ISO Class 2.  ISO Class 2 encompasses IBC Type IIIA and IBC Type IIIB.  Regardless of whether the IBC classification is A (protected) or B (unprotected) the ISO Class is 2. IBC Type IV is Heavy Timber construction and is considered ISO Class 2. The reason is that the heavy timbers perform well and do not fail early in a fire.
# Building elements:<br><br> Joisted Masonry buildings are buildings with exterior walls of masonry or fire-resistive construction rated for not less than one hour and with combustible floors and roofs. There are several types of masonry used in the exterior bearing walls of joisted masonry buildings:
+
# Building elements: Joisted Masonry buildings are buildings with exterior walls of masonry or fire-resistive construction rated for not less than one hour and with combustible floors and roofs. There are several types of masonry used in the exterior bearing walls of joisted masonry buildings:
 
#* brick
 
#* brick
 
#* concrete — either reinforced or non reinforced
 
#* concrete — either reinforced or non reinforced
Line 66: Line 66:
 
#* stone
 
#* stone
 
#* note that exterior bearing walls may also be any noncombustible materials with fire-resistance ratings of not less than one hour
 
#* note that exterior bearing walls may also be any noncombustible materials with fire-resistance ratings of not less than one hour
# Variations: <br><br> There's one variation on joisted masonry construction that doesn't change the construction class — heavy timber or mill construction. Heavy timber construction uses wood members much larger than those found in frame (Construction Class 1) or other joisted masonry construction. If the building uses steel columns or beams for walls, the beams must be protected so they have a fire-resistance rating of not less than one hour. Heavy Timber Construction (IBC Type IV); ISO classifies the building as heavy timber construction if it meets these requirements:
+
# Variations: There's one variation on joisted masonry construction that doesn't change the construction class — heavy timber or mill construction. Heavy timber construction uses wood members much larger than those found in frame (Construction Class 1) or other joisted masonry construction. If the building uses steel columns or beams for walls, the beams must be protected so they have a fire-resistance rating of not less than one hour. Heavy Timber Construction (IBC Type IV); ISO classifies the building as heavy timber construction if it meets these requirements:
 
#* walls of masonry construction
 
#* walls of masonry construction
 
#* floors of {{convert|3|in|cm|adj=on|1}} wood plank or {{convert|4|in|cm|adj=on|1}} laminated plank, both surfaced with {{convert|1|in|cm|adj=on|1}} flooring
 
#* floors of {{convert|3|in|cm|adj=on|1}} wood plank or {{convert|4|in|cm|adj=on|1}} laminated plank, both surfaced with {{convert|1|in|cm|adj=on|1}} flooring
Line 82: Line 82:
  
 
=== Light Noncombustible (ISO Class 3, IBC Type IIB) ===
 
=== Light Noncombustible (ISO Class 3, IBC Type IIB) ===
# Classification: <br><br>Light Noncombustible construction is ISO Class 3.  ISO Class 3 encompasses IBC Type IIB (unprotected).
+
# Classification: Light Noncombustible construction is ISO Class 3.  ISO Class 3 encompasses IBC Type IIB (unprotected).
# Building elements:<br><br> Light Noncombustible buildings are buildings with exterior walls of light metal or other noncombustible material and with noncombustible floors and roofs:
+
# Building elements: Light Noncombustible buildings are buildings with exterior walls of light metal or other noncombustible material and with noncombustible floors and roofs:
 
#* buildings with exterior walls, floors, and roofs of noncombustible or slow-burning materials
 
#* buildings with exterior walls, floors, and roofs of noncombustible or slow-burning materials
 
#* building supports of noncombustible or slow-burning materials
 
#* building supports of noncombustible or slow-burning materials
Line 98: Line 98:
  
 
=== Masonry Noncombustible (ISO Class 4, IBC Type IIA) ===
 
=== Masonry Noncombustible (ISO Class 4, IBC Type IIA) ===
# Classification: <br><br>Masonry Noncombustible construction is ISO Class 4.  ISO Class 4 encompasses IBC Type Type IIA (protected).
+
# Classification: Masonry Noncombustible construction is ISO Class 4.  ISO Class 4 encompasses IBC Type Type IIA (protected).
# Building elements:<br><br> Masonry Noncombustible buildings are buildings with exterior walls of masonry material and with noncombustible or slow burning floors and roofs.
+
# Building elements: Masonry Noncombustible buildings are buildings with exterior walls of masonry material and with noncombustible or slow burning floors and roofs.
 
#* buildings with exterior walls of masonry — not less than four inches thick, or
 
#* buildings with exterior walls of masonry — not less than four inches thick, or
 
#* buildings with exterior walls of fire-resistive construction — with a rating of not less than one hour, and
 
#* buildings with exterior walls of fire-resistive construction — with a rating of not less than one hour, and
Line 111: Line 111:
  
 
=== Modified Fire Resistive (ISO Class 5, IBC Type IB) ===
 
=== Modified Fire Resistive (ISO Class 5, IBC Type IB) ===
# Classification: <br><br>Modified Fire Resistive construction is ISO Class 5.  ISO Class 5 encompasses IBC Type IB.
+
# Classification: Modified Fire Resistive construction is ISO Class 5.  ISO Class 5 encompasses IBC Type IB.
# Building elements:<br><br> Modified Fire Resistive Buildings are buildings where the exterior bearing walls and load-bearing portions of exterior walls must be of noncombustible materials or of masonry, but exterior nonbearing walls and wall panels may be slow-burning, combustible, or with no fire- resistance rating.
+
# Building elements:  Modified Fire Resistive Buildings are buildings where the exterior bearing walls and load-bearing portions of exterior walls must be of noncombustible materials or of masonry, but exterior nonbearing walls and wall panels may be slow-burning, combustible, or with no fire- resistance rating.
 
#* Buildings with exterior walls, floors, and roofs of masonry materials described in the definition of fire resistive (Construction Class 6) — less thick than required for fire-resistive structures but not less than four inches thick, or
 
#* Buildings with exterior walls, floors, and roofs of masonry materials described in the definition of fire resistive (Construction Class 6) — less thick than required for fire-resistive structures but not less than four inches thick, or
 
#* Fire-resistive materials with a fire-resistance rating less than two hours but not less than one hour
 
#* Fire-resistive materials with a fire-resistance rating less than two hours but not less than one hour
Line 136: Line 136:
  
 
=== Fire Resistive (ISO Class 6, IBC Type IA) ===
 
=== Fire Resistive (ISO Class 6, IBC Type IA) ===
# Classification: <br><br>Fire Resistive construction is ISO Class 6.  ISO Class 6 encompasses IBC Type IA.
+
# Classification: Fire Resistive construction is ISO Class 6.  ISO Class 6 encompasses IBC Type IA.
# Building elements:<br><br> The exterior bearing walls and load-bearing portions of exterior walls must be of noncombustible materials or of masonry, but exterior nonbearing walls and wall panels may be slow-burning, combustible, or with no fire-resistance rating.
+
# Building elements:  The exterior bearing walls and load-bearing portions of exterior walls must be of noncombustible materials or of masonry, but exterior nonbearing walls and wall panels may be slow-burning, combustible, or with no fire-resistance rating.
 
#* Walls:
 
#* Walls:
 
#** solid masonry, including reinforced concrete not less than four inches thick
 
#** solid masonry, including reinforced concrete not less than four inches thick
Line 148: Line 148:
 
#* Structural metal supports:
 
#* Structural metal supports:
 
#** Horizontal and vertical load-bearing protected metal supports — including pre-stressed and post-tensioned concrete units — with not less than a two-hour fire-resistance rating
 
#** Horizontal and vertical load-bearing protected metal supports — including pre-stressed and post-tensioned concrete units — with not less than a two-hour fire-resistance rating
# Variations: <br><br>Both '''pre- and post-tensioned concrete''' units have steel cables installed in the concrete to provide tensile strength. With pre-stressed concrete units, builders pull the cables tight before pouring the concrete and release them as the concrete cures. With post-tensioned concrete units, builders pull one end of the cable tight after pouring the concrete.
+
# Variations: Both '''pre- and post-tensioned concrete''' units have steel cables installed in the concrete to provide tensile strength. With pre-stressed concrete units, builders pull the cables tight before pouring the concrete and release them as the concrete cures. With post-tensioned concrete units, builders pull one end of the cable tight after pouring the concrete.
 
# Advantages:
 
# Advantages:
 
#* uses noncombustible materials
 
#* uses noncombustible materials
Line 159: Line 159:
 
== Tips ==
 
== Tips ==
  
* An ISO-IBC conversion table. Click to enlarge. <br><br>
+
* An ISO-IBC conversion table. Click to enlarge.  
  
 